CODAN 5900 High Power VSAT Ku-Band Transceivers



VSAT Transceiver Codan 5900 High Power

CODAN 5900 series VSAT Ku band transceivers offer a wide range of distinctive advantages and enhanced features for satellite communications systems based in remote or challenging geographic regions.

Available in single or dual synthesiser options, Ku-Band frequency bands and 70 or 140MHz IF configurations-and a range of power outputs- CODAN  5900 series VSAT transceivers provide industry leading technical performance.

Key features

Durability

The CODAN 5900 series VSAT transceivers are designed and tested to meet their performance specifications in an ambient temperature range from -40°C to +55°C, ensuring long-term survival in extreme conditions. Field experience shows that MTBFs of greater than 60,000 hours can be expected.

RF performance

RF performance is superb, particularly intermodulation performance, gain stability over temperature and flatness across the IF band.

These transceivers also boast industry leading spurious and harmonics specifications while guaranteed RF performance ensures expensive system link margins do not have to be used to cope with RF transceiver variations. The high linearity and low spurious characteristics contribute to superior multi-carrier performance.

Output power options

The CODAN 5900 series Ku-Band VSAT transceiver is available with 40 watts output rating.

Power consumption

CODAN high power VSAT transceivers low power consumption and low temperature rise, ensuring internal components do not suffer undue stress.

Power supply

All the high power transceivers are AC mains powered and may be field selected to operate from either 115 V AC or 230 V AC.

Internal protection

Internal protection against high temperature and short or open circuit RF output is standard.

Advanced features 

CODAN VSAT Transceiver Ku band Redundancy Switching System

Enhanced monitor and control

All operating functions can be controlled and monitored via the serial interface, and the operating configuration is stored in EEPROM to ensure the set-up parameters are restored in the event of a power failure.

Universal interface compatibility

The CODAN 5900 series VSAT transceivers has universal interface compatibility capable of operating with dumb terminals, laptop/PC emulating terminals, handheld terminals and personal organisers without requiring proprietary software. The versatile configuration options support contact closure, RS232, RS422 and RS485 (2 or 4 wire).

Two dedicated controllers are available from Codan:

  • CODAN 5560 Hand-Held Controller, suitable for in the field installation setup
  • CODAN 5570 Remote Controller, suitable for indoor rack mounting to provide permanent monitoring and control capabilities

Redundancy switching system

A redundancy switching system is available to provide an automatic changeover to a second transceiver to maximise availability and minimise any disruption to service. This system is fully outdoor mounted, but can be supplied with the CODAN 5587 Redundant System Monitor to provide indoor monitoring and control.

CODAN VSAT Transceiver 5560 Hand-held Controller CODAN VSAT Transceiver 5570 Remote Controller

Major configuration options

VSAT Ku-Band transmit frequency band (GHz) - Transmit 

1 VSAT Ku-Band standard

14.00-14.50

VSAT Ku-Band receive frequency bands

All systems use the common CODAN 5900 series VSAT converter module, which has an RF input of 950-1700 MHz. Receive bands are selected by the use of an appropriate LNB. Standard frequency bands are listed below.

VSAT Ku Band LNB (Standard noise temperature 90 K)

Band 1

10.95-11.7 GHz
Band 2 11.7-12.2 GHz
Band 3 12.25-12.75 GHz

(LNBs are phase locked to the internal 10 MHz reference in the 5900 converter module).

Bandwidth

N - Narrow band (40MHz)

Field selectable 70 or 140MHz IF

W - Wide band (80 MHz)

140 MHz IF only


Output power

VSAT Ku-Band: 40W

WR75 waveguide output standard

Options and accessories
  • CODAN Hand-Held Controller
  • CODAN Remote Controller
  • CODAN Redundancy Switching Systems
  • CODAN Transmit Reject Filters
  • CODAN Antenna Mounting Kits

CODAN quality and service

The high power transceivers are built and tested in CODAN ISO9001 quality certified manufacturing facility, and undergo 100% burn in and performance monitoring.

CODAN fully trained staff and agents provide in-factory and in-country training services and complete installation and on-site assistance. This service is backed up by a 24 hour customer service line and a warranty of three years on manufacturing, design or component defects.

Technical specifications

Transmit section

IF input

Frequency range

Narrow BW option
Wide BW option



70 + 20 MHz/140 + 20 MHz selectable
140 + 40 MHz

Impedance

50/75 Ω selectable

Connector

N-type female

Return loss 18 dB minimum at 50

Gain specification

Gain
78 dB minimum (0 dB SSPA & Converter attenuator settings)

 

Attenuator ranges

0 to 25 dB nominal (Converter)
0 to 20 dB nominal (SSPA)

Attenuator step size

1 dB nominal

Gain flatness

Over IF
Narrow BW option
Wide BW option

Over frequency range




±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz

±2.0 dB maximum

Gain stability

+1.5 dB maximum, -40°C to +50°C

RF output

Frequency range

14.0 to 14.5 GHz

Connector

WR75

VSWR

1.25:1 maximum

Output power (1 dB GCP) +46 dBm (40W) minimum at 25°C
Carrier to intermodulation ratio -25 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
Spurious output

-60 dBc maximum at 1 dB GCP

Harmonics

-50 dBc maximum at 1 dB GCP

Phase noise (SSB)*

100 Hz

-60 dBc/Hz maximum

1 kHz

-70 dBc/Hz maximum

10 kHz

-75 dBc/Hz maximum

100 kHz --85 dBc/Hz maximum

Synthesiser step size

Synthesiser step size

1 MHz

Frequency stability

-40°C to +55°C

±2õ10-8

Aging

±1õ10-7/year

Receive section (excluding LNB)  

RF input

Frequency range

950 to 1700 MHz

Impedance

50 Ω

Connector

N-type female

VSWR

1.4:1 maximum
Noise figure 20 dB typical

DC output (switch selectable)

+15 V @ 75 to 400mA

10 MHz output 0 dBm + 1 dB

IF output

Frequency range

Narrow BW option
Wide BW option



70 + 20 MHz/140 + 20 MHz selectable
140 + 40 MHz

Impedance

50/75 Ω selectable

3rd order intercept +15 dBm minimum

Connector

N-type female

Return loss

18 dB minimum at 50 Ω

Gain specification

Gain

35 dB nominal

Attenuator range

0 dB to 25 dB nominal

Attenuator step size

1 dB nominal

Gain flatness

Over IF
Narrow BW option
Wide BW option

Over frequency range




±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz

+2.0 dB maximum

Gain stability

±3.0 dB maximum, -40°C to +55°C

Image rejection 50 dB minimum

Spurious output

-65 dBm maximum

Phase noise (SSB)*

100 Hz

-60 dBc/Hz maximum

1 kHz

-70 dBc/Hz maximum

10 kHz

-80 dBc/Hz maximum

100 kHz

-90 dBc/Hz maximum

Synthesiser step size

Synthesiser step size

1 MHz

Frequency stability

-40°C to +55°C

±2õ10-8

Aging

±1õ10-7/year

Low noise block cconverter

Indicative specifications.

Input

Pass band

10.95 to 12.75 GHz

Insertion loss

0.05 dB maximum

Reject band

13.75 to 14.5 GHz

Rejection

55 dB minimum

Noise figure

Noise figure

1.2 dB @ 25°C maximum
1.0 dB typical

Gain specification

Gain

60 dB typical

Gain flatness

±1.5 dB minimum maximum full band

Output

1 dB GCP

0 dBm minimum

3rd order intercept

+11 dBm minimum

Impedance

50 Ω

Connector

N-type female

VSWR 1.5:1 typical

Transmit reject filter (optional)

Frequency range

VSAT Band 1
VSAT Band 2
VSAT Band 3



10.95 to 11.7 GHz
11.7 to 12.2 GHz
12.25 to 12.75 GHz

Interface

WR75

VSWR

2.5:1 typical

Monitor and control

Monitor and control facilities (converter)

Indicators

Standby, On, Warm-up, SSPA activated, Converter fault, LNB fault, SSPA fault, Temperature fault.

Controls

Power control (off/standby/on), SSPA control (inhibit/remote/ activate), Serial interface settings, LNB supply via Rx RF input connector, Mains/Battery supply select.

Remote monitor and control facilities (only via converter)

Serial interface standards

RS 232, RS 422(RS 485)

Protocol standards

ASCII, Packet (RS 485)

Packet protocol address range 0 to 127

Monitor and control facilities (SSPA)

Remote monitoring functions (serial interface)

 

Standby, On, Warm-up, SSPA activated, Converter temperature, Converter fault, LNB fault, SSPA fault, Temperature fault, SSPA inhibit control, SSPA activate control, Transmit frequency, Receive frequency, Transmit attenuation, Receive attenuation, Cable compensation, Reference oscillator override, SSPA alarm enable, LNB alarm enable, Temperature compensation select, Packet address (ASCII mode only), Packet address range (ASCII mode only), Packet protocol select (ASCII mode only), SSPA mode select, Converter lock, Status change poll.

Remote control functions (serial interface)

Power control (standby/on), SSPA inhibit control, SSPA activate control, Transmit frequency, Receive frequency, Transmit attenuation, Receive attenuation, Cable compensation, Reference oscillator override, SSPA alarm enable, LNB alarm enable, Temperature compensation select, Address range select (ASCII mode only), Packet protocol select (ASCII mode only), SSPA mode select, Reset, Reset change bits.

Remote monitoring functions (contact closure)

Standby, Warm-up, SSPA activated, Converter fault, LNB fault, SSPA fault, Temperature fault.

Remote control functions (contact closure)

Power control (standby on), SSPA inhibit control, SSPA activate control.

Power 

Input voltage

104 to 274 V AC, 47 to 63 Hz

Power consumption 500 VA typical, SSPA on

Environmental

Converter module

Temperature

-40°C to +55°C

Relative humidity

100%

Cooling

Convection

Weatherproofing

Sealed to 34 kPa

SSPA module

Temperature

-40°C to +50°C

Relative humidity

100%

Cooling

Forced air

Weatherproofing

Sealed to IP66

Physical

All dimensions are measured over the connectors.

Size

Converter module

110 mm W x 410 mm D x 240 mm H

SSPA module

280 mm W x 355 mm D x 495 mm H

Weight

Converter module

8 kg

SSPA module

27 kg

 

Indicators

Online, Alarm, Standby, Maintenance

Display Output power, Heatsink temperature, Alarms

Controls

State, Gain